Characteristics 78987

Possibility of manual or fully automatic control and measurement of pressure release in the test line
Constant flow / variable flow / cyclic tests
Constant flow: only 0.5 liters of water are required for testing
Variable flow: Reynolds number requires a 3 L sample and a 90 second test; range of Reynolds numbers from 6000 to 80,000
Variable flow testing saves about a month compared to other testing methods
Stainless steel pipe, ID = 5 mm x 3.5 m (ID = 3 mm or other pipe dimensions on request)
Turbulent flow with maximum kinematic viscosity 45 cSt (ID= 5 mm)
Maximum Reynolds number 80,000 (lD = 5 mm, 1 cSt)
Small required sample volume: from 0.5 l to 3 l
Temperature range: -10 to +80 °C (+14 to +176 °F)
Maximum pressure 35 bar (3.5 MPa, 507 psi)
Chemically immune to most oils/fuels (stainless steel, PEEK, PTFE, SCF)
Industrial control equipment "SPS", software for automatic equipment control
Panel computer, 15“ LCD monitor, Windows XP, equipment for processing analog and digital data
TR-Control software, including full automation of measurements, data processing / visualization, the ability to conduct 24-hour continuous tests, the ability to export data to Excel
Software: TR_EvaluationTool allows you to calculate the effectiveness of ATP and export data to Excel
The entire measuring stand is very compact and built into an aluminum casing
Noise suppression system, oil re-cooling heat exchanger
Spare parts for 2 years service life
Required voltage 380 V, current 16 A, hydraulic booster, 6 bar (0.6 MPa), 1 l/min